Search for this:
 Search these answers
1 through 10 of 58 similar documents, best matches first.
Results by:Thunderstone  Page: 1 2 3 4 5 6   next>>
1: Hallikainen Instruments Boiling Point Analyzer Model 1340
INDUSTRIAL and SCIENTIFIC BOILING POINT ANALYZER COALESCER bv-pass, one for water, an Mid-Range Model Sun Oil Company Design Model 1340 The Mid-Range Model BOILING ...
http://plaintext.hallikainen.org/org/hi/brochures/1340.pdf
97%**********
Size: 3.2M
Depth: 2
Find Similar
Match Info
Show Parents
2: Hallikainen Instruments Boiling Point Analyzer - End Point Model ...
samples and measures the boiling point (ASTM 85 70 to 97% recovered) of hydrocarbon samples in the temperature range of 150' to 700°F. Fast response time [about three ...
http://plaintext.hallikainen.org/org/hi/brochures/1238.pdf
95%**********
Size: 5.6M
Depth: 2
Find Similar
Match Info
Show Parents
3: Hallikainen Instruments Boiling Point Analyzer Models 1007, 1347 ...
BOILING POINT ANALYZER, operates in the Initial to 20% recovered range. APPLICATIONS The analyzer has been successfully applied to many plant streams including several ...
http://plaintext.hallikainen.org/org/hi/brochures/1007.pdf
95%**********
Size: 5.9M
Depth: 2
Find Similar
Match Info
Show Parents
4: Hallikainen Instruments Distillation Analyzer Model 1463
test method, the results may be readily correlated with the ASTM boiling points. APPLICATIONS Several typical applications for the Analyzer are listed below Catalytic ...
http://plaintext.hallikainen.org/org/hi/brochures/1463.pdf
94%*********_
Size: 3.7M
Depth: 2
Find Similar
Match Info
Show Parents
5: Hallikainen Instruments Reflux End Point Analyzer Model 1353A
use of the analyzer is in measuring the temperature of products coming from debutan- izers. deproponizers, etc. in order to determine whether or not heavy ends are ...
http://plaintext.hallikainen.org/org/hi/brochures/1353a.pdf
91%*********_
Size: 2.8M
Depth: 2
Find Similar
Match Info
Show Parents
6: Hallikainen Instruments - Analyzer Summary
by setting the incom- ing and outgoing liquid flow rates to the analyzer. A thermocouple measures a liquid temperature at the established vapor~liquid ratio. This ...
http://plaintext.hallikainen.org/.../brochures/analyzers.pdf
83%********__
Size: 1.9M
Depth: 2
Find Similar
Match Info
Show Parents
7: Hallikainen Instruments Gravitrol Density Analyzer Mark IV Model ...
on site for any density span within the range of the meter, *Higher sensi*ivity with long term stability *Sample loop easily cleaned on site WORKING PRINCIPLE The ...
http://plaintext.hallikainen.org/...i/brochures/gr400967.pdf
82%********__
Size: 2.7M
Depth: 2
Find Similar
Match Info
Show Parents
8: Hallikainen Instruments Process Cloud Point Analyzer Model 1466
D97-IP 15 method. Detection is not affected by the water content or color of the sample. The analyzer has CI cloud point temperature range from -30-F to +55*F (-35-C ...
http://plaintext.hallikainen.org/org/hi/brochures/1466.pdf
76%********__
Size: 3.2M
Depth: 2
Find Similar
Match Info
Show Parents
9: Hallikainen Instruments Product Brochures
viscometer, vapor pressure analyzer, Gravitrol liquid density analyzer, percent evaporation analyzer, low range boiling point analyzer, freezing point analyzer, process ...
http://plaintext.hallikainen.org/org/hi/brochures/
75%********__
Size: 5K
Depth: 1
Find Similar
Match Info
Show Parents
10: Hallikainen Instruments Freezing Point Analyzer Model 1470
and SClENTlflC FREEZING POINT ANALYZER MODEL 1470 Introduction The Model 1470 Freezing Point Anolyax I:, u continuous process analyzer that rne~sures the freezing ...
http://plaintext.hallikainen.org/...brochures/fpa100-468.pdf
74%*******___
Size: 2.4M
Depth: 2
Find Similar
Match Info
Show Parents
1 through 10 of 58 similar documents, best matches first.
  Page: 1 2 3 4 5 6   next>>
Texis & Webinator Copyright (c) 2003 THUNDERSTONE - EPI, Inc.