1: | Hallikainen Instruments Boiling Point Analyzer - End Point Model ... Tower upsets ore immediately indicated by a change in analyzer output. 5. Close-Cut Fractions - A boiling point analyzer will monitor close-cut fractions so that ... http://plaintext.hallikainen.org/org/hi/brochures/1238.pdf | 97% Size: 5.6M Depth: 2 Find Similar Match Info Show Parents |
2: | Hallikainen Instruments Boiling Point Analyzer Models 1007, 1347 ... returned to the process line. A constant sample flow rate is provided by o Hills-McCanno Masterline metering pump. The metered sample flows into o tube in tube heat ... http://plaintext.hallikainen.org/org/hi/brochures/1007.pdf | 96% Size: 5.9M Depth: 2 Find Similar Match Info Show Parents |
3: | Hallikainen Instruments Distillation Analyzer Model 1463 sample is metered to the Analyzer by one head of a duplex pump at a rate of 25 ml/min. Before entering the analyzer, the sample is preheated in a tube-in-tube heat ... http://plaintext.hallikainen.org/org/hi/brochures/1463.pdf | 96% Size: 3.7M Depth: 2 Find Similar Match Info Show Parents |
4: | Hallikainen Instruments Boiling Point Analyzer Model 1340 Model 1340 The Mid-Range Model BOILING POINT ANALYZER operates in the 30% to 70% recovered range. This analyzer is, in effect, a single stoge still to which sample ... http://plaintext.hallikainen.org/org/hi/brochures/1340.pdf | 88% Size: 3.2M Depth: 2 Find Similar Match Info Show Parents |
5: | Hallikainen Instruments Reflux End Point Analyzer Model 1353A from ASTM Dl837- 61T test and, (3) reduce the requirement for laboratory tests. A continuous record always provides more use- ful information than a number of spot ... http://plaintext.hallikainen.org/org/hi/brochures/1353a.pdf | 78% Size: 2.8M Depth: 2 Find Similar Match Info Show Parents |
6: | Hallikainen Instruments Process Cloud Point Analyzer Model 1466 D97-IP 15 method. Detection is not affected by the water content or color of the sample. The analyzer has CI cloud point temperature range from -30-F to +55*F (-35-C ... http://plaintext.hallikainen.org/org/hi/brochures/1466.pdf | 70% Size: 3.2M Depth: 2 Find Similar Match Info Show Parents |
7: | Hallikainen Instruments Continuous Analyzer For Sulfuric Acid ... main- taining the acid strength in the reactor somewhat above the desired minimum in order to provide a factor of safety. Figure 1 shows a graph of settled spent ... http://plaintext.hallikainen.org/org/hi/brochures/1024.pdf | 69% Size: 5.0M Depth: 2 Find Similar Match Info Show Parents |
8: | Hallikainen Instruments Vapor Pressure Analyzer Model 1354 pressure is normally a specifica- within ASTM D-323 procedure. The VAPOR PRESSURE ANALYZER can provide a signal directly in terms of RVP. The anelyzer is adj&ted ... http://plaintext.hallikainen.org/org/hi/brochures/1354.pdf | 68% Size: 2.5M Depth: 2 Find Similar Match Info Show Parents |
9: | Hallikainen Instruments - Analyzer Summary ANALYZER. Output from the analyzer is a single thermocouple which measures the resoective boiling point as the analyzer is cycled. CONTINUOUS VISCOMETER This CONTINUOUS ... http://plaintext.hallikainen.org/.../brochures/analyzers.pdf | 68% Size: 1.9M Depth: 2 Find Similar Match Info Show Parents |
10: | Hallikainen Instruments Product Summary polymers. A built-in recorder is featured together with a temperature controller that can be set to control the sample cell temperature between 35O and 135OC. The ... http://plaintext.hallikainen.org/...hi/brochures/summary.pdf | 68% Size: 2.0M Depth: 2 Find Similar Match Info Show Parents |